Power Module for IGBT Driver

Mornsun power modules for IGBT drivers adopt the mode of mutual connection after two independent outputs makes it better to power up IGBT drivers’ turn-on and turn-off. Meanwhile, the modules feature output short-circuit protection, which can be widely used in frequency transformer / AC servo drive system / welding equipment / UPS.
Series Vin (VDC)Operating TemperaturePositive Output (VDC)Negative Output (VDC)Iout (mA)Efficiency (%)Isolation (VAC)PackageFeatures3D Impression Drawing (.stp)CertificationDatasheetSample
QAUxx
24(9~36)-40~105℃2424150/085%4200DIP24Input Under-voltage Protection-----
QAU242D2G24(9~36)-40~105℃2424150/085%4200VACDIP24Input Under-voltage Protection-
QA051C
5(±10%)-40~105℃20-580/-4079%3000VACSIP7Short-Circuit Protection-----
QA051C5(±10%)-40~105℃20-580/-4079%3000VACSIP7Short-Circuit Protection-
QA151M
15(13.5~16.5)-40~105℃15-5100/-10080%3500VACSIPShort-Circuit Protection-----
QA151M15(13.5~16.5)-40~105℃15-5100/-10080%3500VACSIPShort-Circuit Protection-
QAxxxD
15(13.5~16.5)-40~85℃15-9200/-20087%4000VACDIPShort-Circuit Protection-----
QA152D15(13.5~16.5)-40~85℃15-9200/-20087%4000VACDIPInput Under-voltage Protection
QA
15(±3%)-40~105℃15-8.780/4080%3000VACSIP7Short-Circuit Protection----
QA0115(±3%)-40~105℃15-8.780/-4080%3000VACSIP7Short-Circuit Protection
QA01-1715(±3%)-40~105℃17-980/-4080%3003VACSIP7Short-Circuit Protection
QA0212(±3%)-40~105℃15-8.780/-4080%3004VACSIP7Short-Circuit Protection
QA0324(±3%)-40~105℃15-8.780/-4080%3005VACSIP7Short-Circuit Protection
QA0412(±25%)-40~105℃15-8100/-8080%3006VACSIP7Short-Circuit Protection
QA01C
15(±10%)-40~105℃20-4100/-10083%3500VACSIP7Short-Circuit Protection----
QA01C15(±10%)-40~105℃20-4100/-10083%3007VACSIP7Short-Circuit Protection
QAxx1
12,15,24(±5%)-40~105℃15-8120/-12081%3000VACSIP7Short-Circuit Protection-----
QA12112(±5%)-40~105℃15-8120/-12081%3000VACSIP7No-load operation allowed-
QA15115(±5%)-40~105℃15-8120/-12081%3000VACSIP7No-load operation allowed-
QA24124(±5%)-40~105℃15-8120/-12081%3000VACSIP7No-load operation allowed-
QA121C2
12(±10%)-40~105℃15-3.5111/-11181%3500VACSIPShort-Circuit Protection-----
QA121C212(±10%)-40~105℃15-3.5111/-11181%3500VACSIPShort-Circuit Protection-
CQAW01
12(7~18)-40~105℃15-9±200/±1083%3000VDCDIP24Short-Circuit Protection-----
CQAW0112(7~18)-40~105℃15-9±200/±1083%3000VDCDIP24Short-Circuit Protection-